Product
introduction
This product is a
kind of specialty ester with high quality, high point point, low pour point,
anti-coking, carbon accumulation resistance, environment friendly. It can
solely blended with other synthetic material, also can be used with PAO and
mineral Base Oil.
Product
Specifications
Item
KV
KV
Viscosity Index
Pour Point
Flash Point
Acid
40℃(mm2/s)
100℃(mm2/s)
(VI)
℃
℃
mgKOH/g
DA 22
7.8
2.4
137
-70
205
0.05
DA31
11.1
3.1
150
-60
220
0.05
DA 32
9.5
2.8
149
-65
207
0.05
DA 34
12
3.2
137
-60
199
0.05
DA 41
14
3.6
144
-57
231
0.05
DA 51
27
5.4
136
-57
247
0.05
TMP108A
20
4.4
140
-53
250
0.05
TMP108B
20
4.4
140
-40
250
0.05
M32
33.8
6.0
122
-45
250
0.05
M46
45.3
7.0
110
-43
250
0.05
M50
57
7.8
100
-43
250
0.05
M68
63
8.8
112
-51
260
0.05
M80
85
9.6
87
-43
250
0.05
TM143
143
13.1
83
-45
280
0.05
TM306
306
20.2
73
-23
280
0.05
Application and
recommended treat rate
Air Compressor Oil
75% max
Hydraulic
Oil
50~90%
Features
Good solubility
with additive. Increase oil polarity.
Increse oil
affinity for metals.
Can be used as
Friction Improver with good anti-friction performance.
Anti-coking and
carbon accumulation resistance. High thermal oxidant stability.
High flash point
and low volatility. Excellent low temperature performance.
High viscosity
index. Good demulsification performance.
Good hydrolytic
stability. It is biodegradable.
Package,
storage and transportation
Packaged in plastic drum, N.W. 200KGS/drum. Stored and
transported as non-dangerous goods, stored in cool, dry and ventilated place.
Base Oil For Air Compressor Oil Air Compressor Oil,Base Oil For Air Compressor Oil,Air Compressor Base Oil,Synthetic Specialty Base Oil Zhengzhou Chorus Lubricant Additive Co.,Ltd. , https://www.cn-lubricantadditive.com
Fire pump controller stop pump method?
XZQP series, XZQB series of fire pump control equipment is designed and produced in accordance with the national fire safety standards GBJ16-1987 "architectural design code for fire protection" and GB50045-1995 "high-rise residential building design code for fire protection", designed for high and low Layer industry, civil construction fire, sprinkler, water curtain, fire hydrant pipe and other feed pump control, to meet the user on a variety of different fire pump control. Today to introduce the fire pump controller which pump stop method. Fire pump controller fire control equipment set manual, automatic control mode, manual operation of the device button on the control panel start and stop the pump, automatically by any of the following centralized control of the pump start and stop: 1, Fire Center DC24V start (power provided by the fire center); 2, each hydrant button switch to start; 3, the fire center button to control the start and stop the pump; 4, spray pipe network pressure switch starting and stopping pumps; 5, electric contact pressure gauge low pressure start Pumps (should have a voltage regulator system) and so on. Lead to the hydrant button, signal lights and lead to the fire control center remote control power supply is AC24V. 100V. Control cabinet has a pump open, pump stop, pump fault passive contact feedback fire center. With the main pump failure, standby pump automatically delay the input function. In addition, the control cabinet can be based on user needs, an increase of dual power automatic switching function, regular automatic inspection and other functions, high-power fire main pump can be used to ease the start-up of the pump on the power grid and pipe network impact. Further Reading: Pumps Valves pipe fittings Exhibition 2016 Exhibition of Information Industry, Internet (Xiamen) Technology Co., Ltd. Author: Asian pumps Network Editor: Yao Xiaoxia (QQ / micro-channel :) (service hotline:)