Ion fan maintenance methods and precautions for use

Ion fan is a kind of electronic product that is used more in the workshop of the factory. The use of ion fan is usually more demanding on the production of the product. The main function of ion fan is to help eliminate static electricity and maintain the surface of the human body and objects. The balance of static electricity makes the surface maintain a harmonious electrical neutrality. The ion fan has the characteristics of small size, light weight and easy installation. It can be installed with building blocks, and it is a trial in various places. Do you know what is the maintenance method of ion fan?

 

离子风机_看图王.jpg


   Ion fan maintenance method

 

1. Turn the governor switch clockwise until the indicator light is on, that is, the fan is turned on to generate ion airflow. If the fan speed is increased, the governor switch can be rotated clockwise; the indicator light that is turned to "off" is off, indicating ion The fan is turned off. To adjust the airflow direction, loosen the bracket torx screws, tilt the body to adjust the up and down position, and then tighten the bracket screws after adjustment. To clean the ion emitter, rotate the cleaning head handle clockwise to stop, and then turn it repeatedly until it is clean.

2. The wind speed and static time of the ion fan are determined by various factors. The two most important reasons are the distance and wind speed of the ion fan. Air ions are constantly neutralizing each other, and cations and anions attract each other through static electricity to form the transfer and recombination of these charges. High wind speed can neutralize them farther away. The higher the wind speed, the faster the neutralization of static electricity. When using an ion fan for electronic assembly, the ionized airflow should cover the working area as much as possible, so that the positive and negative charges on the surface of the object can be well neutralized, so that it maintains the neutral state.

3. To clean the launch point of the transmitter, rotate the cleaning head handle clockwise to release it after stopping, and then turn it repeatedly until it is clean, at least once a week. The air inlet net and the ionization outlet net should be kept clean to prevent blocking airflow, and can be cleaned with a soft brush or compressed air.

4. Use a plate load monitor to measure, or use an ion tester to measure ion balance. The test instrument brand is CIMCO (ME-268A) in the United States, or the ion balancer (residual voltage) is used to measure the ion balance (residual voltage). The output design of the ion fan for the ion quantity is stable and fixed. Due to the possibility of being affected by factors such as voltage fluctuations and ambient air dry humidity, an offset in ion balance may be formed.

 

   Precautions for using ion fan

 

1. The ion fan inoculation is required to be carried out in a closed room;

2. The metal part of the ion fan is susceptible to corrosion by fumigation such as sulfur or aerosol disinfectant. During fumigation, the ion fan should be taken out of the department, and the metal part in front of the ion fan should be covered when spray disinfection Pole discharge

3. Half an hour before inoculation, spray 2% ~ 3% coal phenol soap or 5% Xinjieer water solution in the room. After purification and disinfection, turn on the ion fan, and inoculate within 20-30 cm effective range in front of the ion fan 5 minutes later;

4. The power supply voltage is required to be stable. Generally, the rural electricity consumption is large at night, and the voltage is low, but the sterilization requirements are not met. It can be used when the voltage is stable during the day;

5. After using the ion fan, you should often wipe the dust on the positive and negative electrodes with cotton dipped in alcohol. Excessive dust absorption will reduce the amount of ionized ozone and will not achieve the sterilization effect;

6. The inoculation personnel should not face the ion fan during the inoculation process, and try to stagger the face and the ion fan's wind-generating part to prevent the symptoms of dizziness and nausea caused by insufficient oxygen supply to the brain caused by long-term inoculation.

The above content is related knowledge about the maintenance methods and precautions for ion fans introduced to friends. For various types of ion fans, generally horizontal ion fans are the most expensive; followed by suspended ion fans and desktop ion fans; and micro ion fans are usually the cheapest. Of course, this is simply compared according to the production cost, and the quality difference is also an important factor in determining the price of the ion fan.