Hans quality Felt Pads, Wool Bonnet & Polishing Bars ar High resistance pad with black velour to one side gives an excellent grip against the backing,Very versatile able to withstand high temperatures and friction levels pad.Ideal for cutting and polishing action resulting in high gloss finish on a range of surfaces such as Glass, Plastic, Metal, Stone and Minerals.Achievebetter shine on stone countertops when using these buffing & shining products,This final polishing pad can be used onsapphire, glass,lapidary and gemstone etc.These polishing pads are 6" diameter and made with high-density wool felt. They have a 3M pressure sensitive adhesive backing on the backside that provides easy application to spin-on discs or backing plates with a stay-put fit. Glass Polish Felt Polishing Pads,Felt Polishing And Buffing Pads,Felt polishing pad,Felt Glass Polishing Pads Hans Superabrasive Material Co., Ltd. , https://www.hansuperabrasive.com
According to Article 40 of the Urban Heating Regulations issued by Heilongjiang in May 2005, the ownership and maintenance of indoor heating facilities for residential users are the responsibility of the owner of the house. Therefore, the geothermal pipeline should be cleaned and maintained in time to prevent clogging.
Second, users who just entered the household still need to clean it?
The need for cleaning, because in the laying of geothermal pipeline construction will leave some impurities in the pipeline, causing the pipeline to cause blockage in a short time. Therefore, when entering the household, it is necessary to inspect the pipeline. If problems are found, clean the pipeline in time to avoid blockage of the pipeline.
Third, the family's high temperature still need to clean it?
The normal geothermal heating should be 24 hours heating, the water temperature is 55 degrees, and now the heating company heating water temperature is around 80 degrees, so the home temperature will be high, but precisely because of this, some owners will provide for The thermal valve shuts down small or closes the one way or the other, causing the water flow in the geothermal pipeline to slow down, accelerating the formation of pipeline deposits, and it is easier to cause embolism, so it should be cleaned in time.
4. During the heating period each year, the water will be discharged, and will it be blocked?
It will be blocked, because a layer of hardened calcium and magnesium ions and biological sludge adhere to the wall of the geothermal heat pipe. Normal exhaust and discharge of water cannot be flushed. The fundamental problem cannot be solved. The wall will gradually thicken if it is not cleaned in time. Narrowing, eventually resulting in blocked use.
5. The water in the boiler room is treated with a lot of muddy water. When the water temperature reaches 30 degrees, it will produce floc, which we call biological sludge in the wall. In addition, the combination of minerals and calcium and magnesium ions in the water and hung on the wall will also form dirt.
Cleaning Q&A There are a lot of users who have called to ask: Do you damage the geothermal pipes during cleaning?
Our company is now responding: No, our cleaning equipment working pressure value is less than or equal to 6 kg, which is the standard capacity of the geothermal pipeline pressure detected before entering the home, so it will not cause pipelines to be washed when cleaning. Any damage.
Ask your company's cleaning equipment to remove pipeline dirt?
Our company responded: Yes, because my company's cleaning equipment is based on the working principle of physical pulse, through the vibration of the emblem wave, water and gas to form a water brush cleaning, and combined with the soaking of drugs, so can put the wall of the Dirt removed.
The necessity of geothermal cleaning
1. Is the homeowner responsible for geothermal cleaning?