Gas water heaters can't be fired, don't worry about it.

Gas water heaters are gas products that every household needs to use. If something goes wrong, don't worry too much.

This is not, recently, a call for help calls into the Qianjiang Gas Company, saying that its own gas water heater suddenly "not light": "This gas water heater has been used for a long time, now every time you have to fire several times to be normal Use, when there is a fire, there will be a smell of gas in the house. Does this matter?"

So, what is the reason for this?

The staff of Qianjiang Gas Co., Ltd. told the reporter that in general, the ignition time of the gas water heater lags behind the gas release time. That is to say, when the gas water heater is turned on, the natural gas will be continuously transmitted to the water heater, but it is not ignited in time. Therefore, there will be cases where it is sometimes used several times to be used normally.

The water heater can not be fired mainly can be divided into two cases: no ignition sound, no ignition and no ignition sound. When the ignition is started, only the ignition sound is heard. There is no magnetic sound of the solenoid valve "å—’", and there may be a malfunction of the solenoid valve, such as damage or aging of the solenoid valve. When the solenoid valve is aging, it will be uncontrolled. It can be sucked at the beginning of the fire, and it will catch fire, but it will close and then turn off. In addition, it may be that the gas pressure is too high or too low, and the water bottle using the cylinder gas will appear. The pressure output of the pressure reducing valve is too high or too low to make the water heater unable to catch fire; or the solenoid valve is dirty.

In addition to the malfunction of the solenoid valve, if one of the pulse igniter and the controller fails, the water heater cannot be normally ignited. There is also a water pressure problem, the water-gas linkage device is faulty, and the tympanic membrane aging or damage in the valve cannot promote the cause of the misfire of the micro-switch. If you find a gas smell when you are on fire, be sure to pay attention. When the gas accumulates to a certain extent and is ignited again, an ignition seedling may cause natural gas deflagration.

Therefore, if there is a problem with the water heater, it is best to ask a professional for repair. Source: Qian Jiang Evening News Hu Shirui

Jc001.load('news_ads'); jc001.newsAds.prints("15")

Grill Grate

BBQ grate,stainless wire grill grate,grill grate,stainless steel bbq grate, iron bbq grate, etc. Suitable for indoor and outdoor barbecue, group activities, increase the fun of life.Multi-functional Grill Cooking Grid Grate: This wire mesh is mainly used for BBQ Grill Mat for outdoor cooking, it can also be used as a cooling and baking rack. Or you can develop other uses for it.