How to use the floating door

You can often see the floating doors around us. This type of door is very convenient to use. No need for manual adjustment when using. As the heart of the floating door, pay attention to the "motor" when using it. Any precautions? Next, let's explain the precautions for the use of the suspension door motor!
1. When the suspension door is opened and closed, pedestrians and vehicles are strictly prohibited from passing through. Since the floating door is connected by a connecting piece when opening and closing, there are almost no unsafe factors in the motor and the transmission shaft. Therefore, it should try not to start running.
2. Buying a suspension door motor is also a more important part. Remember not to think that the lifting force is sufficient, because the bearing capacity of the suspension door motor will gradually reduce the actual lifting effect over time, so choose as many materials as possible. It must exceed the suspension. The actual operating force of the door.
3. When opening and closing the suspension door, check if there is any tilt. Suspension doors are often damaged or tilted due to improper operation. Special attention should also be paid to the fact that the suspension door should be on site while opening and closing. When the door is tilted or the track is stuck, it should be stopped and closed in time to avoid more damage to the motor and the door.
4. Manufacturers should also consider more lightweight, durable materials when selecting materials for suspension doors, so that they can play a higher safety even under special circumstances.

Gin Pole Operations

On the documentation side on things, operator will need adequate details depicting the planned operational configuration(s) for the complete gin pole system to be used including:

•Gin pole mast

•Top lifting block

•Load and tag line sizes/configuration (including use of heel block, max load position angle, max tag angle, tag arrangement, etc.)

•Basket and bridle attachment to gin pole and supporting structure including associated hardware and sling sizes/config

•All relevant details pertaining to jumping/lowering the pole into position

•All relevant details pertaining to tilting the pole for operation (use of luffing block, etc.)

•Any other relevant details based upon user`s planned operational configurations for assembly, setting, jumping, arranging, lifting, and/or removal of the system

As pole manufacture MARSHINE we only address the gin pole mast and allowable load and tag capacities / angles based solely upon the mast`s rated strength.  Affirming the pole was designed, built and load charts are in accordance with the ANSI/TIA-322 standard.  Its operator responsibility to ensure they are in compliance with all regulations related thereto.

Complete records of pole inspections and record of Magnetic particle inspection shall be performed on 10% of the welded connections every 10 years.

Annual inspections reports shall be maintained for a minimum of two years.

All gin pole operations must be in compliance with the latest revision of ANSI/TIA-322 and the OSHA CPL 2-1.36

 Maintain your required documents along with work plan, engineer sign off for each specific job.

ANSI/TIA-322 standard includes an impact factor of 1.7 for all gin poles using synthetic load lines.  

 

Gin Pole storage racks for gin poles are recommended for safe transport, storage and return shipping for inspection service. These units protect and reduce the potential of damage from excess handling with forks etc.

gin-pole-1

Gin Pole

Tower Gin Pole,Stringing Euqipment Gin Pole,Tubular Gin Pole,Aluminum Alloy Gin Pole

NINGBO MARSHINE POWER TECHNOLOGY CO., LTD. , https://www.marshine-power.com