>>>Classification of Interior Wall Coatings Suitable for a variety of fine wood finishes, advanced plastering finishes, block facings, metal finishes, paper finishes, soft pack finishes, and glass curtains as the base for the finish. Guaranteed items 1. The basement project must be flat, with vertical facades, flat joints, square corners, and precise dimensions. Wall Construction Acceptance Paint Glass Stainless Steel Aluminum Alloy
2. The structure of steel and wood frame partition walls must meet the requirements of the drawings and construction specifications. The connectors of the light steel frame should meet the product mix requirements.
3. The installation position of steel and wooden keel (rest bars) must be correct, the connection is firm, safe and reliable, no bending, deformation, wooden parts without cracking, in line with the requirements of safe use.
1. The filling material in the wall must be dry, full, firm, and not sagging. The paving thickness should be uniform and consistent with the design requirements.
2. When metal mesh is used as a plastering base, it must be nailed firmly and pinned. Joints on the main skeleton of the frame must not have any edges. The bond between the substrate ash and the substrate must be firm and there must be no delamination, hollowing and cracking of the ash.
3. The base material with a piece of decorative material must be solid and clean. The materials for sticking and dry hanging must meet the construction specifications and design requirements.
4. The substrate with a coating or paste finish must meet the following requirements: Quality requirements for the plastered surface: The plastering surface meets the high plastering standards. The ash surface has the same color. When using the fabric with low hiding power, the gray surface should be pure white.
5. Quality requirements based on plywood and gypsum plasterboard: Plywood and gypsum plasterboard are applied to the surface of water-resistant panels. The surface is clean and smooth, the cut surface is neat, the joints are tight, there is no hanging glue, no exposed nail caps, and the skeleton tightly and firmly.
6. The surface of the metal plate substrate with a painted finish shall not contain oil, rust, scale, welding slag, and burrs.
7. The paste and coating project require that the base moisture content should meet the following requirements: Concrete surface and plaster surface should not exceed 8%. The wooden board surface is not more than 10%.
8. The flatness, verticality and reserved hole of the glass curtain wall substrate shall meet the construction specifications and design requirements, and the error must be within the adjustable range of the connector.
9. The connection between the hidden frame glass and the structure must adopt the method of pre-embedded iron. The fasteners connected to the aluminum alloy must use stainless steel.
Inspection method: Observe, pull the handle, pull the ruler, tap with a small hammer to check, check the test record.
Base Works Acceptance Specification - Wall Base Works